Skip to main navigation Skip to search Skip to main content

A rotational ablation tool for calcified atherosclerotic plaque removal

  • Min Hyeng Kim
  • , Hyung Jung Kim
  • , Nicholas N. Kim
  • , Hae Sung Yoon
  • , Sung Hoon Ahn
  • Seoul National University

Research output: Contribution to journal › Article › peer-review

38 Scopus citations

Abstract

Atherosclerosis is a major cardiovascular disease involving accumulations of lipids, white blood cells, and other materials on the inside of artery walls. Since the calcification found in the advanced stage of atherosclerosis dramatically enhances the mechanical properties of the plaque, restoring the original lumen of the artery remains a challenge. High-speed rotational atherectomy, when performed with an ablating grinder to remove the plaque, produces much better results in the treatment of calcified plaque compared to other methods. However, the highspeed rotation of the Rotablator commercial rotational atherectomy device produces microcavitation, which should be avoided because of the serious complications it can cause. This research involves the development of a highspeed rotational ablation tool that does not generate microcavitation. It relies on surface modification to achieve the required surface roughness. The surface roughness of the tool for differential cutting was designed based on lubrication theory, and the surface of the tool was modified using Nd:YAG laser beam engraving. Electron microscope images and profiles indicated that the engraved surface of the tool had approximately 1 μm of root mean square surface roughness. The ablation experiment was performed on hydroxyapatite/polylactide composite with an elastic modulus similar to that of calcified plaque. In addition, differential cutting was verified on silicone rubber with an elastic modulus similar to that of a normal artery. The tool performance and reliability were evaluated by measuring the ablation force exerted, the size of the debris generated during ablation, and through visual inspection of the silicone rubber surface.

Original languageEnglish
Pages (from-to)963-971
Number of pages9
JournalBiomedical Microdevices
Volume13
Issue number6
DOIs
StatePublished - Dec 2011

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Calcified atherosclerotic plaque
  • Laser beam engraving
  • Rotational Atherectomy (RA)
  • Surface modification

Fingerprint

Dive into the research topics of 'A rotational ablation tool for calcified atherosclerotic plaque removal'. Together they form a unique fingerprint.

Cite this