Skip to main navigation Skip to search Skip to main content

Cardiovascular hardware simulator and artificial aorta-generated central blood pressure waveform database according to various vascular ages for cardiovascular health monitoring applications

  • Jae Hak Jeong
  • , Bomi Lee
  • , Junki Hong
  • , Changhee Min
  • , Adelle Ria Persad
  • , Tae Heon Yang
  • , Yong Hwa Park
  • Korea Advanced Institute of Science and Technology

Research output: Contribution to journal › Article › peer-review

8 Scopus citations

Abstract

This study presents a database of central blood pressure waveforms according to cardiovascular health conditions, to supplement the lack of clinical data in cardiovascular health research, constructed by a cardiovascular simulator. Blood pressure (BP) is the most frequently measured biomarker, and in addition to systolic and diastolic pressure, its waveform represents the various conditions of cardiovascular health. A BP waveform is formed by overlapping the forward and reflected waves, which are affected by the pulse wave velocity (PWV). The increase in vascular stiffness with aging increases PWV, and the PWV-age distribution curve is called vascular age. For cardiovascular health research, extensive data of central BP waveform is essential, but the clinical data published so far are insufficient and imbalanced in quantity and quality. This study reproduces the central BP waveform using a cardiovascular hardware simulator and artificial aortas, which mimic the physiological structure and properties of the human. The simulator can adjust cardiovascular health conditions to the same level as humans, such as heart rate of 40–100 BPM, stroke volume of 40–100 mL, and peripheral resistance of 12 steps. Also, 6 artificial aortas with vascular ages in the 20–70 were fabricated to reproduce the increase in vascular stiffness due to aging. Vascular age calculated from measured stiffness of artificial aorta and central BP waveform showed an error of less than 3 years from the clinical value. Through this, a total of 636 waveforms were created to construct a central BP waveform database according to controlled various cardiovascular health conditions.

Original languageEnglish
Article number108224
JournalComputers in Biology and Medicine
Volume172
DOIs
StatePublished - Apr 2024

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Ageing
  • Aorta
  • Blood pressure waveform
  • Cardiovascular health monitoring
  • Cardiovascular simulator
  • Central blood pressure
  • Heartrate
  • Peripheral resistance
  • PWV
  • Stroke volume
  • Vascular age

Fingerprint

Dive into the research topics of 'Cardiovascular hardware simulator and artificial aorta-generated central blood pressure waveform database according to various vascular ages for cardiovascular health monitoring applications'. Together they form a unique fingerprint.

Cite this