Abstract

This paper analyzes CCM/DCM operations of three-level boost (TLB) converter and derives ideal duty-ratios for feedforward control in power factor correction (PFC) applications. The analyses are conducted for two different TLB operation modes characterized by input voltage range. Since duty-ratio feedforward is a widely used technique to improve PFC transient responses and mitigate the burden of feedback control, accurate duty-ratio computations for all possible operation modes and conduction modes are necessary. By comparing the derived duty-ratios for CCM and DCM regions, current conduction modes of TLB can be detected in real-time and proper duty-ratio feedforward with minimum duty-ratio selection can be provided. The experimental results by a 500 W prototype of TLB PFC rectifier are provided in order to verify the effectiveness of the derivations and feedforward technique.

Original languageEnglish
Title of host publication34th Annual IEEE Applied Power Electronics Conference and Exposition, APEC 2019
PublisherInstitute of Electrical and Electronics Engineers Inc.
Pages1173-1179
Number of pages7
ISBN (Electronic)9781538683309
DOIs
StatePublished - 24 May 2019
Event34th Annual IEEE Applied Power Electronics Conference and Exposition, APEC 2019 - Anaheim, United States
Duration: 17 Mar 2019 → 21 Mar 2019

Publication series

NameConference Proceedings - IEEE Applied Power Electronics Conference and Exposition - APEC
Volume2019-March

Conference

Conference34th Annual IEEE Applied Power Electronics Conference and Exposition, APEC 2019
Country/TerritoryUnited States
CityAnaheim
Period17/03/19 → 21/03/19

Keywords

  • CCM
  • DCM
  • Feedforward
  • Ideal duty-ratio
  • Power factor correction (PFC)
  • Three-level boost (TLB)

Fingerprint

Dive into the research topics of 'Derivation of DCM/CCM boundary and ideal duty-ratio feedforward for three-level boost rectifier'. Together they form a unique fingerprint.

Cite this