N2 - In this paper, a new switching control method for light load efficiency improvement in phase shifted full bridge (PSFB) converter is proposed. The main advantage of the proposed method is that it does not use any additional component in power conversion stage, so that it does not have any additional loss. By using simple 'AND-gated' control signals for synchronous rectifier (SR) and optimized dead time for primary switches, it is possible to get not only reduced core losses, but also ZVS operation even in light load condition. Therefore, the proposed switching control method reduces switching and core losses in light load condition so that it shows remarkably increased light load efficiency. The feasibility of the proposed switching control method has been verified by experimental results with 90-264Vac input, 400V link voltage, 12V output voltage, and 750W output server computer power supply system.
AB - In this paper, a new switching control method for light load efficiency improvement in phase shifted full bridge (PSFB) converter is proposed. The main advantage of the proposed method is that it does not use any additional component in power conversion stage, so that it does not have any additional loss. By using simple 'AND-gated' control signals for synchronous rectifier (SR) and optimized dead time for primary switches, it is possible to get not only reduced core losses, but also ZVS operation even in light load condition. Therefore, the proposed switching control method reduces switching and core losses in light load condition so that it shows remarkably increased light load efficiency. The feasibility of the proposed switching control method has been verified by experimental results with 90-264Vac input, 400V link voltage, 12V output voltage, and 750W output server computer power supply system.
KW - Light load efficiency improvement
KW - phase shifted full bridge converter (PSFB)
KW - synchronous rectifier (SR) control
UR - https://www.scopus.com/pages/publications/84883707242
U2 - 10.1109/ECCE-Asia.2013.6579091
DO - 10.1109/ECCE-Asia.2013.6579091
M3 - Conference contribution
AN - SCOPUS:84883707242
SN - 9781479904822
T3 - 2013 IEEE ECCE Asia Downunder - 5th IEEE Annual International Energy Conversion Congress and Exhibition, IEEE ECCE Asia 2013
SP - 165
EP - 169
BT - 2013 IEEE ECCE Asia Downunder - 5th IEEE Annual International Energy Conversion Congress and Exhibition, IEEE ECCE Asia 2013
T2 - 2013 IEEE ECCE Asia Downunder - 5th IEEE Annual International Energy Conversion Congress and Exhibition, IEEE ECCE Asia 2013
Y2 - 3 June 2013 through 6 June 2013
ER -